Maintenance schedule
Check all external screw connections for tight fit approx. 8 hours after first operation.
Parts Maintenance jobs Maintenance interval
Air filter Check for external damage and tight daily
fit.
Check foam and filter insert clean or replace if
necessary.
Fuel Check tank lid for tightfit, replace if
necessary.
Engine oil Check oil level, top up if necessary.
Other parts Check cutting disc for damages and correct tightenning
- change and or adjust if necessary. Pay attention
to the directional arrow on the disc.
Control smooth working of the height adjustment.
Control water supply.
Belts Check tension and wear – replace if necessary. weekly
Engine oil First oil change. 20 hours
Air filter Clean. 50 hours
Ignition system Clean spark plug, check spark plug gap 0,7 mm. 100 hours
Engine oil Furhter oil changes.
Valve clearance Check, set - 0,15 mm intake valve, 0,20 mm exhaust 300 hours
valve.