Wacker Neuson EHB 10 series Manuale dell'Operatore Pagina 43

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
Vedere la pagina 42
EHB 11 Maintenance
43
8.2.3 Checking the tool holder for wear
1. Insert the tool.
Note: Use a new tool to measure only the wear of the tool holder and not the
wear of the tool.
2. Measure the tool play 200 mm from insertion point.
Play may not exceed 6 mm.
If the play exceeds 6 mm, the tool holder must be replaced.
Item Value
A200 mm
B Max. 6 mm
Vedere la pagina 42